TC8235GIT Ground loop isolation transformer

Commercial Type No.: TC8235GIT
Product No.: 4.998.138.485

TC8235GIT Ground loop isolation transformer
  • Ground isolation for 75 Ohm video/data lines
  • 10 Hz to 7 MHz bandwidth
  • Low insertion loss
  • Insulated BNC connectors
  • Excellent discrimination against power line inter-ground potentials
  • Easy installation
  • Details
    Impedance Levels 75 Ω unbalanced, input and output
    Insertion Loss 0.5 dB at 1 kHz
    Return Loss Better than 20 dB,120 Hz to 5 MHz
    Sine Wave Transmission (Bandwidth)
    Amplitude Flat loss is 0.45 dB maximum at 15 kHz, 3 dB down relative mid-frequency response at 10 Hz and 7 MHz
    Phase Linear with slope of 18°/MHz, 1 MHz to 5 MHz
    Ground Isolation En/Eo = 115 dB at 60 Hz (decreases with frequency at 6 dB/octave to 30 dB minimum at 1 MHz
    Dielectric Withstanding Voltage
    500 Vrms, 60 Hz (from connectors to case and each other)
    Weight 223 g (0.5 lb)
    Finish Black