Analog Accessories


 
FMR-1000-RA LCD annunciator FPA-1000 without control
  • LED status indicators
  • 80‑character LCD display
  • Piezo sounder
  • Navigation buttons
  • Acknowledge key
 
 
FMR-1000-RCMD LCD annunciator FPA-1000 with control
  • LED status indicators
  • 80‑character LCD display
  • Piezo sounder
  • Navigation buttons
  • Operations keys for drill, reset, silence, and acknowledge
 
 
FLM-325-I4-A Contact Monitors
  • Monitors Normally Open (NO) or Normally Closed (NC) contacts
  • Monitored Normally Closed (NC) contacts can be configured with or without EOL resistor
  • Module address programming with the D5070 Analog Device Programmer
  • Bi‑colored LED provides module status
  • Digital data communications and power over a two‑wire circuit
  • EEPROM addressing
 
 
FLM-325-2R4-A Dual Relay Modules
  • Two independently configurable Form C contacts
  • Contacts are rated 1 A at 30 VDC or 0.5 A at 125 VAC
  • Module address programming with the D5070 Analog Device Programmer
  • Bi‑colored LED provides module status
  • Digital data communications and power over a two‑wire circuit
 
 
FLM-325-NA4 Supervised Output Modules
  • Contacts are rated 2 A at 24 VDC
  • Flexible application and quick response to emergency conditions
  • Can be alarmed or reset by zone or by individual address
  • Module address programming with the D5070 Analog Device Programmer
  • Bi‑colored LED provides module status
  • Digital data communications and power over a four‑wire circuit
 
 
FLM-325-CZM4 Conventional zone module for FPA-1000
  • Provides a zone of up to 25 conventional smoke detectors (depending on detector type)
  • Supervises auxiliary power supply for conventional detectors
  • Compatible with Class B (Style B) or Class A (Style D)
  • Module address programming with the D5070 Analog Device Programmer between 1 and 127
  • Bi‑colored LED provides module status
  • Digital data communications and power over a four‑wire circuit
 
 
D7035 Octal Relay Modules
  • Eight Form C programmable relay outputs
  • D7035 mounts conveniently inside the FACP enclosure; no separate enclosure needed
  • D7035B includes mounting skirt and enclosure for mounting outside of the FACP enclosure
  • Up to two modules are supported by the FACP
 
 
FLM-325-ISO Short circuit isolator for FPA-1000
  • Automatic verification of data line for short circuit
  • Contacts are rated to 1 A at 30 VDC
  • Can be placed at any location on SLC loop
  • 256 devices at maximum per loop for Class A (Style 7)
  • Yellow LED provides data line status
 
 
FPE-1000-SLC Plug-in SLC module for FPA-1000
  • Signaling Line Circuit (SLC) is power-limited and supervised
  • Configurable as one Class X or Class A or two Class B circuits
  • Up to 254 detectors and modules, or 127 analog sounder bases in combination with suitable detectors
 
 
FPE-1000-NE Network card, 3-Ethernet
  • Provides three Ethernet ports using CAT 5 or better cable
  • Uses simple plug-in connection to the FPA‑1000‑V2
  • Connects as either Class A or Class B
  • Uses standard RJ45 connections
  • Provides second power input port for normal network operation during maintenance
 
 
FPE-1000-NF Network card, 1-Ethernet 2-fiber optic
  • Provides media type change through RJ45 and fiber optic connections
  • Provides one Ethernet port using CAT 5 or better cable
  • Uses simple plug-in connection to the FPA‑1000‑V2
  • Connects as either Class A or Class B
  • Provides second power input port for normal network operation during maintenance
 
 
FPE-1000-NW Network card, 1-Ethernet 2-wired
  • Provides media type change through RJ45 and wired connections
  • Provides one Ethernet port using CAT 5 or better cable
  • Uses simple plug-in connection to the FPA‑1000‑V2
  • Connects as either Class A or Class B
  • Provides second power input port for normal network operation during maintenance
 
 
FAA-325-10 Sample tube, duct 10'/304.8cm
  • Metal tube with air sampling holes
  • Tubes connect to each other and to housing using standard ½” collets
  • End plug provided
 
 
FAA-325-5 Sample tube, duct 5'/152.4cm
  • Metal tube with air sampling holes
  • Tubes connect to each other and to housing using standard ½” collets
  • End plug provided
 
 
FAA-325-2.5 Sample tube, duct 2.5'/76.2cm
  • Metal tube with air sampling holes
  • Tubes connect to each other and to housing using standard ½” collets
  • End plug provided
 
 
FMM-100GR Break rods, scored acrylic, 12pcs
  • Scored for clean breaking
  • Lightweight acrylic
  • Comes in packages of 12
 
 
FLM-325-2I4 Dual input module for FPA-1000
  • Two independent contact monitoring circuits
  • Monitors Normally Open (NO) or Normally Closed (NC) contacts
  • Monitored Normally Open (NO) contacts can be configured with or without EOL resistor
  • Module address programming with the D5070 Analog Device Programmer between 1‑127
  • Bicolored LED provides module status
  • Digital data communications and power over a two‑wire circuit