FCP‑500 Conventional Automatic Fire Detectors

FCP‑500 Conventional Automatic Fire Detectors
  • Modern, ultra-flat design
  • Matches the surrounding decor by using color toning inserts
  • Smooth, easily-cleaned detector surface
  • Innovative fastening mechanism
  • High reliability
  • Details
    Operating voltage 8.5 V DC bis 33 V DC
    Standby current
    FCA-500-EU 3 mA
    FCA-500-E-EU 24 mA
    Alarm current 47 mA
    Fault current
    FCA-500-EU 52 mA
    FCA-500-E-EU 58 mA
    Alarm resistance 0 Ω (UL application) or 680 Ω
    Fault relay output NC / C
    Indicator output Relay connects 0 V over 1.5 kΩ
    Individual display Two-color LED, red (alarm), green (test mode)
    Dimensions
    Detector Ø 113 x 55 mm
    Detector with trim ring Ø 150 x 55 mm
    Detector with cover, base and ceiling mount back box Ø 150 x 110 mm
    Housing material Polycarbonate
    Housing color Signal white, RAL 9003
    Front plate color
    FCP‑O 500/ FCP‑OC 500 Signal white matt
    FCP‑O 500‑P/ FCP‑OC 500‑P Transparent/silver-gray
    Weight Without / with packaging
    FCP-OC 500(-P) 180 g / 370 g
    FCP-O 500(-P) 170 g / 360 g
    Trim Ring 30 g / 60 g
    Protection class as per EN 60529
    FCP‑O 500 (‑P) IP 53
    FCP‑OC 500 (‑P) IP 33
    Permissible operating temperature
    FCP‑O 500 (‑P) -20 °C bis +65 °C
    FCP‑OC 500 (‑P) -10 °C bis +50 °C
    Permissible relative humidity 95% (non-condensing)
    Permissible air speed 20 m/s
    Monitoring area Max. 120 m2(Heed local guidelines!)
    Maximum installation height Max. 16 m(Heed local guidelines!)
    Minimum installation height Out of arm's reach Minimum installation height recommended by BOSCH: 2.70 m
    In the case of flush ceiling mounting with ceiling mount back box
    Thickness of the false ceiling Max. 32 mm
    Required bored hole Ø 130 mm (-1 mm bis +5 mm)
    Installation depth 110 mm Note: Above the false ceiling, a free height of at least 110 mm is required.
    Minimum distance to lamps 0.5 m
    Detection principle
    FCP‑O 500 (‑P) Scattered light measurement
    FCP‑OC 500 (‑P) Combination of scattered light measurement and combustion gas measurement
    Features
    All FCP‑500 detectors Contamination detection Drift compensation (optical section)
    In addition, for FCP‑OC 500(-P) Drift compensation in the gas sensor section
    Response sensitivity
    FCP‑O 500 (‑P) < 0.18 dB/m ( EN 54‑7)
    FCP‑OC 500 (‑P) Optical section: < 0.36 dB/m (EN 54‑7) Gas sensor section: in ppm range

    Images

     

    Features

    vds
     
  • Certificates (5)
    Title Type Language
    Declaration of Conformity PDF
    VdS PDF
    VdS PDF
    CPD PDF
    CPD PDF
     
  • Documents (9)
     
 

Product variants

FCP-O 500 Smoke detector optical, white

conventional detector with optical sensor, ultra-flat design

Commercial Type No.: FCP-O 500
Product No.: F.01U.510.649

 
FCP-O 500-P Smoke detector, optical, color inserts

conventional detector with optical sensor and ultra-flat design, transparent with color inserts

Commercial Type No.: FCP-O 500-P
Product No.: F.01U.510.654

 
 
FCP-OC 500 Detector, optical/chemical, white

conventional detector with optical and chemical sensor, ultra-flat design

Commercial Type No.: FCP-OC 500
Product No.: F.01U.510.653

 
FCP-OC 500-P Detector optical/chemical, color inserts

conventional detector with optical and chemical sensor, ultra-flat design, transparent with color inserts

Commercial Type No.: FCP-OC 500-P
Product No.: F.01U.510.656

 
 

Accessories

FAA-500-TR-W Trim ring, white

FAA-500-TR-W Trim ring, white

for 500 and 520 Series Fire Detectors

Commercial Type No.: FAA-500-TR-W
Product No.: 4.998.151.295

 
FAA-500-TR-P Trim ring, colored

FAA-500-TR-P Trim ring, colored

for 500 and 520 Series Fire Detectors

Commercial Type No.: FAA-500-TR-P
Product No.: 4.998.151.296

 
 
FCA-500-EU Detector base, conventional

FCA-500-EU Detector base, conventional

for the FCP‑-500 Series detectors

Commercial Type No.: FCA-500-EU
Product No.: F.01U.510.647

 
FCA-500-E-EU Detector base, conventional, end-of-line

FCA-500-E-EU Detector base, conventional, end-of-line

for the FCP‑500 Series detectors, with integrated EOL resistor

Commercial Type No.: FCA-500-E-EU
Product No.: F.01U.510.648

 
 
FAA-500-BB Back box ceiling-mount

FAA-500-BB Back box ceiling-mount

for ceiling flush installation in false ceilings when mounting 500 and 520 Series Bases and Fire Detectors

Commercial Type No.: FAA-500-BB
Product No.: 4.998.151.302

 
FAA-500-CB Housing for concrete ceilings

FAA-500-CB Housing for concrete ceilings

for installing 500 and 520 Series Fire Detectors in concrete ceilings. In addition, you need to order a FAA‑500‑BB Back box ceiling-mount.

Commercial Type No.: FAA-500-CB
Product No.: F.01U.508.713

 
 
FAA-500-SB-H Back box for damp rooms, surface-mount

FAA-500-SB-H Back box for damp rooms, surface-mount

for special applications where it is not possible to flush-mount the 500 and 520 Series Fire Detectors in a ceiling

Commercial Type No.: FAA-500-SB-H
Product No.: F.01U.510.166

 
FAA-500-SPRING Spring for wooden/concrete ceilings

FAA-500-SPRING Spring for wooden/concrete ceilings

(DU = 10 units)

Commercial Type No.: FAA-500-SPRING
Product No.: F.01U.510.028